//
Warning: Cannot modify header information - headers already sent by (output started at /home/etdlibitenasac/public_html/index.php:1) in /home/etdlibitenasac/public_html/sysconfig.inc.php on line 185

Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; StringReader has a deprecated constructor in /home/etdlibitenasac/public_html/lib/lang/php-gettext/streams.php on line 48

Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; FileReader has a deprecated constructor in /home/etdlibitenasac/public_html/lib/lang/php-gettext/streams.php on line 84

Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; CachedFileReader has a deprecated constructor in /home/etdlibitenasac/public_html/lib/lang/php-gettext/streams.php on line 145

Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; gettext_reader has a deprecated constructor in /home/etdlibitenasac/public_html/lib/lang/php-gettext/gettext.php on line 36

Warning: session_start(): Cannot start session when headers already sent in /home/etdlibitenasac/public_html/index.php on line 38

Warning: Cannot modify header information - headers already sent by (output started at /home/etdlibitenasac/public_html/index.php:1) in /home/etdlibitenasac/public_html/lib/contents/show_detail.inc.php on line 42
<![CDATA[KENDALI TEGANGAN AC DENGAN MENGGUNAKAN IC TCA 785 BERKAPASITAS 1000 WATT PADA PEMANAS]]> 0414085703 - Ir. Nasrun Hariyanto, M.T Dosen Pembimbing 1 0402056403 - Sabat Anwari, M.T. Dosen Pembimbing 2 Arinda Febriani Mahesa Putri / 11-2013-073 Penulis
Alat pemanas digunakan pada setrika, oven, microwave, water heater, penetas telur, dan lain-lain. Setiap peralatan pemanas mempunyai tingkat panas yang berbeda-beda. Oleh karena itu diperlukan suatu alat pengendalian tingkat panas. Pengaturan tingkat panas dilakukan dengan mengubah-ubah sudut penyalaan, dengan merubah sudut penyalaan maka tegangan keluaran berubah. Pengaturan sudut penyalaan dilakukan dengan menggunakan IC TCA 785 dan komponen thyristor. Rangkaian kendali tegangan AC berkapasitas 1000 watt. Kendali tegangan AC dengan menggunakan komponen thyristor. Hasil penelitian didapat, pada sudut penyalaan 30° tegangan keluaran 216,8 volt, pada sudut penyalaan 60° tegangan keluaran 197,3 volt, pada sudut penyalaan 90° tegangan keluaran 155,56 volt, pada sudut penyalaan 120° tegangan keluaran 97,27 volt, dan pada sudut penyalaan 150° tegangan keluaran 37,34 volt. Komponen daya yang dipakai adalah thyristor scr.